Access Granted
Free Preview
Physical Sciences • Practical #117 Interactive Simulation Available

Stewart & Gee's Tangent Galvanometer Virtual Laboratory

The Stewart & Gee's Tangent Galvanometer Virtual Laboratory is an interactive physics simulation designed to investigate the spatial variation of the magnetic field along the axis o...

Physics Stewart & Gee's Tangent Galvanometer Virtual Laboratory ID: 117
AI Topic: Electrical Machines & Transformers
Stewart & Gee's Tangent Galvanometer Virtual Laboratory 3D Topic Apparatus
Electrical Power Engineering
Public Preview Mode Sign in to track progress pathway, generate AI quizzes, record completion, and access protected simulators.
ADVERTISEMENT
Experiment Progress Pathway
0%

The Stewart & Gee's Tangent Galvanometer Virtual Laboratory is an interactive physics simulation designed to investigate the spatial variation of the magnetic field along the axis of a current-carrying circular coil and to determine Earth's horizontal magnetic field ($B_H$). Built with high-precision scalable vector graphics (SVG) and real-time Chart.js plotting, the simulator replicates the complete bench apparatus, including a 40 cm graduated mahogany and brass rail, a multi-tap vertical circular coil ($n = 2, 50, 500$ turns), a sliding magnetometer compass carriage, and a reversing commutator key.Students can switch seamlessly between Dual View (Bench + Compass Preview), a 3D Realistic Galvanometer Model, a Magnified Compass Dial with an anti-parallax mirror ring, and Field Curve Analysis to map the bell-shaped magnetic field profile $B(x)$ and locate its points of inflection at $x = \pm R/2$.

Axial Magnetic Field Verification: Measure the magnetic field $B(x)$ at varying axial distances ($-20\text{ cm}$ to $+20\text{ cm}$) from the center of a current-carrying circular coil and verify the Biot-Savart axial relation $B(x) = \frac{\mu_0 n I R^2}{2(R^2 + x^2)^{3/2}}$.Tangent Law Application: Apply the tangent law of magnetism ($B = B_H \tan\theta$) to determine Earth's horizontal magnetic field component ($B_H$) from compass deflection angles.Error Elimination via Commutator: Record all four pointer readings ($\theta_1, \theta_2$ for direct current $+I$, and $\theta_3, \theta_4$ for reversed current $-I$) at each position to eliminate zero-shift, coil misalignment, and parallax errors.Points of Inflection & Helmholtz Principle: Plot $B(x)$ vs. $x$ to identify the points of inflection at $x = \pm R/2$, where $\frac{d^2B}{dx^2} = 0$ and the field gradient becomes linear.

Stewart & Gee Bench Assembly: 40 cm graduated brass millimeter scale rail ($-20\text{ cm}$ to $+20\text{ cm}$) supporting a vertical circular coil with selectable turn taps ($n = 2, 50, 500$ turns) and configurable radius ($R = 10.0\text{--}15.0\text{ cm}$).Sliding Magnetometer Compass Box: Movable carriage housing a pivoted magnetic needle, perpendicular aluminum pointer, $0^\circ\text{--}90^\circ\text{--}0^\circ\text{--}90^\circ$ graduated dial, and anti-parallax mirror ring.Electrical Circuit & Control Deck: DC power supply, ammeter ($0.00\text{--}1.00\text{ A}$), rheostat current slider, and a 4-way reversing commutator switch ($+I / -I$).Data Logger & Analytical Suite: Automated bench scanner, 4-reading observation table with mean $\theta$ and $\tan\theta$ computation, CSV exporter, and real-time $B(x)$ curve plotter.

Step 1: Meridian Alignment & Initial CalibrationClick Verify 0°–0° to confirm the coil plane is aligned parallel to Earth's magnetic meridian (North–South) so the perpendicular aluminum pointer reads $0^\circ\text{--}0^\circ$ with zero current.Select the desired number of coil turns (e.g., 50 Turns) and adjust the Electric Current ($I$) to $0.25\text{ A}$ so deflection at the center ($x = 0\text{ cm}$) lies within the optimal sensitivity range ($30^\circ\text{--}60^\circ$).Step 2: Direct Current Measurements ($+I$)Ensure the commutator switch is set to Normal (+I).Position the sliding compass carriage at $x = 0.0\text{ cm}$ using the Axial Distance ($x$) slider or quick presets.Observe the magnified compass dial (aligning the pointer with its mirror reflection to avoid parallax) and click Record Reading to log Direct End 1 ($\theta_1$) and Direct End 2 ($\theta_2$).Step 3: Reversed Current Measurements ($-I$)Toggle the commutator switch to Reversed (-I) to reverse the current direction through the coil.Click Record Reading at the same axial position to log Reversed End 3 ($\theta_3$) and Reversed End 4 ($\theta_4$).Step 4: Axial Profile Scan & Inflection Point AnalysisRepeat direct and reversed readings at $2.0\text{ cm}$ intervals on both sides of the coil ($-20.0\text{ cm}$ to $+20.0\text{ cm}$), or click Auto-Scan Bench to sweep automatically.Switch to Field Curve Analysis to inspect the symmetrical bell-shaped $B(x)$ curve, verify peak field at $x = 0\text{ cm}$, and locate the inflection points at $x = \pm R/2$ ($\pm 6.0\text{ cm}$ for $R = 12.0\text{ cm}$).Click Export CSV to download the complete observation table for calculating $B_H$.

AI Knowledge Evaluation

10 AI-generated multiple-choice questions tailored to this practical. Score 7/10 (70%) or higher to verify experiment completion.

Student Authentication Required
Please login to your account to generate the quiz, record marks, and earn completion credit.
Interactive Simulation Sandbox

Initializing secure sandbox environment & decrypting simulation...

ADVERTISEMENT
× ❮ ❯

Practical Report Issue

Reporting for: Stewart & Gee's Tangent Galvanometer Virtual Laboratory

Developer Inspection Restricted

Developer Tools and source inspection are restricted on this platform to protect intellectual property and proprietary virtual laboratory simulations.

Welcome to Community Chat!

📢 Community Chat is Now Live

Connect with fellow learners in real-time! You can ask questions, share experiences, collaborate on experiments, and learn together.

Real-time messaging
Group discussions
File sharing
Online/offline presence

⚠️ Important Guidelines

  • Be respectful and professional
  • No spam, harassment, or inappropriate content
  • Keep discussions educational and relevant
  • Violations may result in warnings or bans

Read Full Community Guidelines →

Chat messages are monitored by the Virtual Lab team to ensure a safe environment. By continuing, you agree to our community guidelines and acceptable use policy.